General info[edit | edit source]

Pull-to-unlock sensor is great if you need players to pull something as a part of a puzzle. It can be easily pulled with not much power but it can withstand heavy weight.

The maximum load of the feeback connector is 50 mA. If you want to connect something with a higher current load, connect an external power supply - then the maximum load is 1A.

Step 1[edit | edit source]

Connect the Pull-to-Unlock sensor to the Universal puzzle controller via included Ethernet cable.

Step 2[edit | edit source]

Connect the Universal puzzle controller to a power supply.

Step 3[edit | edit source]

Add a chain, rope, or some other way players can pull the sensor.

Step 4[edit | edit source]

Whenever the sensor is pulled, the sensor becomes triggered and its red diode lights up.